Power Generator Rental across Saudi Arabia
Diesel and silent generators 20–1250 kVA for prime and standby power. Same-day delivery in major cities. Fuel service, cabling, distribution boards, and 24/7 support.
Why RJC for Generators
Nationwide Coverage
Riyadh, Jeddah, Dammam, Makkah, Madinah, Tabuk, NEOM, Yanbu, Abha, Jazan, and remote sites.
Reliability & Compliance
Maintained to OEM schedules, calibrated meters, load test reports, and earthing kits.
Flexible Contracts
Daily, weekly, monthly, and long-term rental with standby and extensions.
24/7 Support
Fuel service, call-outs, and replacement units if downtime exceeds the window.
Generator Types

Silent Canopy
Low-noise sets for events, offices, malls, hospitals, and data halls.
- Range: 20–500 kVA
- Integrated bunded tanks
- RCD protection available
- External sockets or hard-wired

Towable / Trailer
Rapid deployment units for sites with frequent moves and night works.
- Range: 40–250 kVA
- Road-legal trailers
- Lockable fuel caps
- Cable ramps on request

Containerized High-Capacity
Prime or standby power for construction, camps, and critical facilities.
- Range: 400–1250 kVA
- External bulk tanks and polishing
- Synchronizing and load sharing
- Remote monitoring options
Sizing Guide
| Load Profile | Recommended Type | Typical Size | Notes |
|---|---|---|---|
| Site office, lights, small tools | Silent canopy | 40–80 kVA | RCDs and distribution boards |
| Events, temporary power | Towable/trailer | 60–200 kVA | Low-noise, rapid deployment |
| Cranes, pumps, tower lights | Containerized | 200–500 kVA | External tanks, synchronizing |
Options & Add-Ons
Cables & Distribution
H07RN-F cables, camlocks, DBs, RCDs, and cable ramps.
ATS & Synchronizing
Automatic transfer switches, multi-set sync, and load sharing.
Fuel Tanks & Service
Bunded bulk tanks, fuel polishing, and scheduled refilling.
Load Bank Testing
Resistive/reactive testing with reports before critical use.
Safety & Compliance
Proper earthing and RCD protection. Fuel spill kits and fire extinguishers on site. Cable routing with ramps and barriers. OEM maintenance records and calibrations.
Generator FAQs
What details do you need to size a generator?
Total load in kW/kVA, starting currents, voltage, phase, duty (prime/standby), site photos, and runtime window.
Do you provide fuel service?
Yes. Bunded bulk tanks with scheduled refills and polishing are available.
Can units run in parallel?
Yes. Synchronizing and load sharing can be set up for redundancy or capacity.
What is the difference between prime and standby?
Prime is continuous duty at variable load. Standby is for emergency use with limited annual hours.